The detector  provides acceptance for Z<sup>0</sup> decays over 4&pi; in solid angle. The main detector components are a system of central tracking chambers inside a solenoidal field of 0.435 T, a time-of-flight counter, a lead glass electromagnetic calorimeter with a presampler, a hadron calorimeter in the form of an instrumented magnet return yoke, and an outer muon chamber. A forward calorimeter serves as a luminosity moniter.
+
The detector  provides acceptance for Z<sup>0</sup> decays over <math>4\pi</math> in solid angle. The main detector components are a system of central tracking chambers inside a solenoidal field of 0.435 T, a time-of-flight counter, a lead glass electromagnetic calorimeter with a presampler, a hadron calorimeter in the form of an instrumented magnet return yoke, and an outer muon chamber. A forward calorimeter serves as a luminosity moniter.
  
 
===Central Tracking Detector===
 
===Central Tracking Detector===
 
The Central Tracking Detector is divided into a precision vertex chamber, a large jet chamber, and a z chamber.
 
The Central Tracking Detector is divided into a precision vertex chamber, a large jet chamber, and a z chamber.
  
The vertex detector is a cylindrical drift chamber that surrounds has a length of 1 m, an inner radius of 88 mm, and an outer radius of 235 mm. There are two layers of 36 cells each: an inner layer of axial wires and an outer layer of stereo cells. Both types of cells have radial wire planes consisting of 200 &mu;m gold plated Cu-Be potential wires and 20 &mu;m gold plated W-Rh andoe wires. In the axial cells, there are 12 anode wires with radial spacing of 5.3 mm. The stereo cells have 6 anode wires with a spacing of 5 mm with a stereo angle of 4 &deg;. The cathode planes use 125 &mu;m Cu-Be wires with a 1 mm spacing in both cells. In the r-&phi; plane, the vertex chamber provides a resolution of 55 &mu;m.
+
The vertex detector is a cylindrical drift chamber that surrounds has a length of 1 m, an inner radius of 88 mm, and an outer radius of 235 mm. There are two layers of 36 cells each: an inner layer of axial wires and an outer layer of stereo cells. Both types of cells have radial wire planes consisting of 200 &mu;m gold plated Cu-Be potential wires and 20 &mu;m gold plated W-Rh andoe wires. In the axial cells, there are 12 anode wires with radial spacing of 5.3 mm. The stereo cells have 6 anode wires with a spacing of 5 mm with a stereo angle of 4 degrees. The cathode planes use 125 &mu;m Cu-Be wires with a 1 mm spacing in both cells. In the r-&phi; plane, the vertex chamber provides a resolution of 55 &mu;m.
  
The jet chamber is absed on the design of the jet chamber in the JADE experiment at PETRA. The inner diameter is 0.5 m and the outer diameter is 3.7 m. The chamber is divided into 24 sectors divided by cathode wire planes. Each sector has a radial wire plane with 159 sensing wires parallel to the beam. For 43&deg; < &theta; < 137&deg;, 159 points will be measured along each track, and at least 8 points are achieved over 98% of the solid angle. The anode wires are spaced 10 mm apart and alternated with potential wires which are set at -2.38 kV. The jet chamber provides a resolution of 135 &mu;m in the r-&phi; plane and 6 cm in the z direction. The dE/dx resoultion is 3.8% in a diumuon sample with at least 130 points per track.
 
 
The z chamber covers 44&deg; < &theta; < 136&deg; and 94% of the azimuthal angle. The purpose is to make a precision measurement of the z coordinate of charged particles that leave the jet chamber. There are 24 drift chambers, each 4 m long, 50 cm wide, and 59 mm thick. Each chamber is divided into 8 cells in z with six anode wires separated by 4 mm in the radial plane but perpendicular to the beam direction. The chamber provides a resolution of 300 &mu;m in z and 1.5 cm in r-&phi;.
 
 
All three chambers use the same gas mixture of argon (88.2%), methane (9.8%) and isobutane (2.0%) at 4 bar. The gas system has a recirculation and purifation system to remove oxygen to a level of a few ppm. A laser system monitors drift velocity at an accuracy of &sigma/v < 0.1%.
 
 
Combined, three chambers provide a resolution of 75 &mu;m in the r-&phi; plane and 2mm in the r-z plane. The invariant mass resolution for K<sup>0</sup> goes to &pi;<sup>+</sup>&pi;<sup>-</sup> is 8 MeV.
 
  
 